SEC-00 / NAV

Key Selling Points

  • Adjustable Protection
  • Residual Current Monitoring
  • Remote Communication

Application Tags

Industrial Power Distribution Panels Commercial Building Electrical Syste... Motor Control Centers Generator Protection

MODEL REF: TDK5

TDK5 Thermal Magnetic MCCB

Thermal Magnetic MCCB Smart MCCB Apr 21, 2026 ENGINEERING SUPPORT AVAILABLE

The TDK5 series offers robust thermal magnetic molded case circuit breakers engineered for dependable overcurrent and short-circuit protection in diverse electrical systems.

Rated Operating Voltage AC400, AC415
Poles 4
Frame Current Range 63A-800A
Standard IEC60947-2
Ultimate Short-Circuit Breaking Capacity Icu 35kA - 50kA
Rated Insulation Voltage Ui 800V - 1000V
Rated Impulse Withstand Voltage Uimp 8kV - 12kV
Total Operational Performance Up to 10,000 cycles

Core Capabilities

Key Features

Robust Circuit Protection

Provides reliable thermal magnetic protection against overloads and short circuits, with ultimate breaking capacities...

Wide Current Frame Range

Available in frame sizes from 63A up to 800A, accommodating a broad spectrum of...

IEC Standard Compliance

Engineered and tested to meet the stringent requirements of IEC60947-2, ensuring global applicability and...

4-Pole Configuration

Designed with a 4-pole structure, suitable for comprehensive protection in three-phase systems with neutral.

Product Brief

Overview

The TDK5 Thermal Magnetic MCCB series delivers essential circuit protection for a wide array of electrical installations. Conforming to the IEC60947-2 standard, these molded case circuit breakers are designed to safeguard circuits from both overcurrents and short-circuit faults, ensuring system integrity and operational continuity.

  • Robust Circuit Protection
  • Wide Current Frame Range
  • IEC Standard Compliance

Selection

Selection / Use Cases

Use this MCCB when:

Leakage Monitoring

Suitable for systems requiring residual current protection and status visibility.

Remote Communication

Supports RS485-based integration for panel and facility monitoring.

Adjustable Protection

Built for load coordination environments that need configurable trip settings.

  • Current Requirements: Select a TDK5 variant based on the required frame current (63A to 800A) and specific rated current (e.g.,...
  • Breaking Capacity: Match the ultimate short-circuit breaking capacity (Icu) of 35kA-50kA to the prospective fault current levels of your electrical...
  • System Voltage: Ensure compatibility with AC400 or AC415 rated operating voltages and consider the insulation voltage (Ui) for system safety.

Resources

CAD / Datasheet / Contact

Datasheet Access

Request Datasheet

Electrical ratings, dimensions, and compliance references for project review.

CAD Support

Request CAD

Drawing files and dimensional references for enclosure and panel coordination.

Engineering Contact

Contact Engineer

Confirm selection, accessories, and project requirements with engineering support.

Technical Data

Technical Specs

Rated Operating Voltage AC400, AC415
Poles 4
Frame Current Range 63A-800A
Standard IEC60947-2
Ultimate Short-Circuit Breaking Capacity Icu 35kA - 50kA
Rated Insulation Voltage Ui 800V - 1000V
Rated Impulse Withstand Voltage Uimp 8kV - 12kV
Total Operational Performance Up to 10,000 cycles
INDUSTRIAL INTEGRITY

STANDARD COMPLIANCE

All components meet IEC 60947-2 and CE certification standards. ISO 9001:2015 certified manufacturing.

OEM/ODM CAPABILITIES

Custom electrical configurations and private labeling for global infrastructure projects.

ENGINEERING ASSETS

Immediate access to 2D/3D CAD models, STEP files, and detailed technical datasheets.

Get a Fast, Accurate Quote for Your Project

Submit your specifications or BOM details. Our engineers will review your requirements and provide a precise quotation within 24 hours.

  • Response within 24 hours
  • Engineering review included
  • Support for OEM and custom specifications

IEC 60947-2 compliant | ISO 9001 certified manufacturing

PRODUCT ID: TDK5