Arc Fault Detection Device (AFDD)
Protect electrical circuits from dangerous arc faults with our reliable Arc Fault Detection Device (AFDDs) for enhanced safety.
- Detects series and parallel arc faults to prevent fires Detects series and parallel arc faults to prevent fires
- Compliant with IEC62606 / IEC60898-1 standards Compliant with IEC62606 / IEC60898-1 standards
- Rated for AC230V, 50Hz systems with 4kV impulse withstand voltage Rated for AC230V, 50Hz systems with 4kV impulse withstand voltage
Family Catalog
Arc Fault Detection Device (AFDD) SKU Pages
This family belongs to Modular DIN Rail Products. Open a product detail page below for detailed specifications, files, and inquiry access.
Family Overview
Selection And Application Context
Arc Fault Detection Device (AFDDs) represent a critical advancement in electrical safety technology, specifically designed to identify and mitigate the risks associated with arc faults. Unlike traditional Miniature Circuit Breakers (MCBs) or Residual Current Circuit Breakers (RCCBs), AFDDs employ sophisticated electronics to differentiate between normal operating arcs (e.g., in switches or motors) and dangerous, sustained arc faults that can generate intense heat and ignite fires. This proactive detection capability is vital for safeguarding both property and lives.
Our AFDDs are built to meet rigorous international standards, including IEC62606 and IEC60898-1, ensuring reliable performance in demanding environments. They are rated for AC230V and 50Hz systems, featuring a rated impulse withstand voltage (Uimp) of 4kV. With options for B, C, and D tripping curves—corresponding to (3-5)xIn, (5-10)xIn, and (10-20)xIn respectively—our AFDDs can be selected to match specific circuit characteristics and load requirements. Installation is straightforward, utilizing standard DIN-rail mounting, and the devices offer an IP20 degree of protection.
Integrating AFDDs into electrical installations, particularly in high-safety residential circuits and premium commercial setups, significantly elevates protection levels. They are indispensable for electrical consultants, specifiers, and OEM panel builders focused on delivering compliant and secure electrical systems. Beyond our standard offerings, we provide ODM and private label manufacturing support, enabling partners to integrate our high-quality AFDD technology under their own brand.
Selection Guide
How to choose the right modular protection device
Use this guide to narrow down the product family by protection function, installation type, and special requirements.
Step 2: Choose installation type
Step 3: Choose special function
Step 4: Choose control or accessories
Select one option in each step to preview matched products.
Feature
Why choose our AFDD?
Use Cases
Typical Applications
High-safety residential circuits
Best for homes and basic distribution boards.
Premium commercial installations
Best for offices and commercial electrical panels.
Electrical distribution panels
Best for industrial control panels and OEM integration.
Renovation and upgrade projects
Suitable for low-voltage distribution and panel integration projects.
TDAFD7 Arc Fault Detection Device (AFDD)
TDAFD7 is part of the Arc Fault Detection Device (AFDD) range for modular low-voltage distribution systems. The model family includes 1 variant option(s) to support practical project selection.
AC220V / 50Hz / DIN-rail Mounting
Best for: Arc fault protection in final circui... / Enhanced fire-safety installations
TDAFD8 Arc Fault Detection Device (AFDD)
TDAFD8 is part of the Arc Fault Detection Device (AFDD) range for modular low-voltage distribution systems. The model family includes 2 variant option(s) to support practical project selection.
Rated making and breakingcapacity (Im) / AC230V / 1P+N
Best for: Arc fault protection in final circui... / Enhanced fire-safety installations
TDAFD1 Arc Fault Detection Device (AFDD)
TDAFD1 is part of the Arc Fault Detection Device (AFDD) range for modular low-voltage distribution systems. The model family includes 1 variant option(s) to support practical project selection.
AC230V / 50Hz / 6-32A
Best for: Arc fault protection in final circui... / Enhanced fire-safety installations
TDAFD2 Arc Fault Detection Device (AFDD)
TDAFD2 is part of the Arc Fault Detection Device (AFDD) range for modular low-voltage distribution systems. The model family includes 1 variant option(s) to support practical project selection.
AC230V / 50Hz / 6-40A
Best for: Arc fault protection in final circui... / Enhanced fire-safety installations
TDAFD3 Arc Fault Detection Device (AFDD)
TDAFD3 is part of the Arc Fault Detection Device (AFDD) range for modular low-voltage distribution systems. The model family includes 1 variant option(s) to support practical project selection.
AC230V / 50Hz / 6-40A
Best for: Arc fault protection in final circui... / Enhanced fire-safety installations
TDAFD4 Arc Fault Detection Device (AFDD)
TDAFD4 is part of the Arc Fault Detection Device (AFDD) range for modular low-voltage distribution systems. The model family includes 1 variant option(s) to support practical project selection.
AC380V/400V / 50Hz / 6-63A
Best for: Arc fault protection in final circui... / Enhanced fire-safety installations
TDAFD5 Arc Fault Detection Device (AFDD)
TDAFD5 is part of the Arc Fault Detection Device (AFDD) range for modular low-voltage distribution systems. The model family includes 1 variant option(s) to support practical project selection.
AC230V/240V / 50Hz / 6-63A
Best for: Arc fault protection in final circui... / Enhanced fire-safety installations
FAQ
Frequently Asked Questions
What is an Arc Fault Detection Device (AFDD)?
Arc Fault Detection Device (AFDD) is an electrical safety device designed to detect dangerous electrical arc faults and quickly disconnect the circuit to prevent fires. It differentiates between...
How do AFDDs enhance electrical safety?
AFDDs enhance safety by identifying and reacting to arc faults that might otherwise go undetected by standard circuit breakers. These faults can generate significant heat and cause electrical...
What standards do your AFDDs comply with?
Our Arc Fault Detection Device comply with international standards IEC62606 and IEC60898-1, ensuring they meet rigorous safety and performance requirements for electrical protection devices.
Where are AFDDs typically installed?
AFDDs are commonly installed in residential and commercial electrical panels, particularly in circuits serving bedrooms, living areas, and other spaces where fire safety is a primary concern. They...
Can I get custom-branded AFDDs for my business?
Yes, we offer ODM (Original Design Manufacturer) and private label manufacturing support for our Arc Fault Circuit Breakers, allowing partners to brand our high-quality products as their own.
Project Inquiry
Secure Your Installations with Advanced AFDDs
Ensure superior electrical safety and fire prevention. Contact Engineer today to discuss your project requirements or to request a detailed quote.
Not sure which model to choose? Talk to an engineer
Visual References
Family Gallery
STANDARD COMPLIANCE
All components meet IEC 60947-2 and CE certification standards. ISO 9001:2015 certified manufacturing.
OEM/ODM CAPABILITIES
Custom electrical configurations and private labeling for global infrastructure projects.
ENGINEERING ASSETS
Immediate access to 2D/3D CAD models, STEP files, and detailed technical datasheets.
REQUIRE CUSTOM SPECIFICATIONS?
Consult with our lead engineers for a specialized BOM or system architecture review.