Plug In RCBO Circuit Breaker
Integrated residual current and overcurrent protection in a convenient plug-in format, designed for rapid installation and enhanced safety.
- Integrated overcurrent and residual current protection Integrated overcurrent and residual current protection
- Plug-in installation for rapid deployment Plug-in installation for rapid deployment
- Available in 1P, 2P, 3P, and 4P configurations Available in 1P, 2P, 3P, and 4P configurations
Family Catalog
Plug In RCBO Circuit Breaker SKU Pages
This family belongs to Modular DIN Rail Products. Open a product detail page below for detailed specifications, files, and inquiry access.
Family Overview
Selection And Application Context
Plug In RCBO Circuit Breakers are engineered to deliver comprehensive electrical protection in a streamlined, user-friendly format. These devices combine the functions of a Miniature Circuit Breaker (MCB) and a Residual Current Circuit Breaker (RCCB), offering protection against overcurrents (overload and short-circuit) and earth leakage faults. The plug-in design significantly simplifies installation, making them a preferred choice for manufacturers of plug-in consumer units and electrical contractors performing retrofit protection upgrades.
Our Plug In RCBOs are available in various pole configurations (1P/2P/3P/4P) and tripping curves (B, C, D) to suit diverse load characteristics and application requirements. They operate at a rated voltage of 230V and a frequency of 50/60Hz, ensuring compatibility with standard electrical systems. With an electrical and mechanical life of 20,000 cycles and an IP20 degree of protection, these electronic model RCBOs are built for durability and consistent performance in demanding environments.
We support ODM and private label manufacturing, allowing panelboard manufacturers and electrical contractors to integrate our high-quality Plug In RCBO Circuit Breakers seamlessly into their product lines or projects. Our range includes both AC and A type residual current protection, with a rated residual operating current of 30mA, providing sensitive detection of earth faults. This integrated approach to protection enhances safety for end-users and simplifies inventory management for distributors and installers. Choose our Plug In RCBOs for reliable, efficient, and compliant electrical safety solutions.
Selection Guide
How to choose the right modular protection device
Use this guide to narrow down the product family by protection function, installation type, and special requirements.
Step 2: Choose installation type
Step 3: Choose special function
Step 4: Choose control or accessories
Select one option in each step to preview matched products.
Feature
Why choose our Plug In RCBO Circuit Breaker?
Use Cases
Typical Applications
Residential plug-in consumer units
Best for homes and basic distribution boards.
Commercial panelboard installations
Best for offices and commercial electrical panels.
Retrofit electrical protection upgrades
Suitable for low-voltage distribution and panel integration projects.
New construction electrical systems
Suitable for low-voltage distribution and panel integration projects.
TD50C Plug In RCBO Circuit Breaker
TD50C is part of the Plug In RCBO Circuit Breaker range for modular low-voltage distribution systems. The model family includes 1 variant option(s) to support practical project selection.
110/230V / 50/60Hz / 10-40A
Best for: Plug-in RCBO retrofit projects / Combined leakage and overcurrent plu...
TD50LE Plug In RCBO Circuit Breaker
TD50LE is part of the Plug In RCBO Circuit Breaker range for modular low-voltage distribution systems. The model family includes 1 variant option(s) to support practical project selection.
220V / 10-40A / 2P1E
Best for: Plug-in RCBO retrofit projects / Combined leakage and overcurrent plu...
TDR8 Plug In RCBO Circuit Breaker
TDR8 is part of the Plug In RCBO Circuit Breaker range for modular low-voltage distribution systems. The model family includes 1 variant option(s) to support practical project selection.
10kA / 230V / 6-63A
Best for: Plug-in RCBO retrofit projects / Combined leakage and overcurrent plu...
TDR12 Plug In RCBO Circuit Breaker
TDR12 is part of the Plug In RCBO Circuit Breaker range for modular low-voltage distribution systems. The model family includes 1 variant option(s) to support practical project selection.
3kA / 230V / 6-32A
Best for: Plug-in RCBO retrofit projects / Combined leakage and overcurrent plu...
FAQ
Frequently Asked Questions
What are the main advantages of plug-in installation?
Plug-in installation significantly reduces wiring time and complexity, leading to faster and more efficient deployment in consumer units and panelboards. It also simplifies maintenance and replacement processes.
What types of protection do these RCBOs offer?
Our Plug In RCBOs provide protection against overloads, short-circuits, and earth leakage currents. They are available in both AC and A types for residual current detection, suitable for...
Can these RCBOs be used in different electrical systems?
Yes, our Plug In RCBOs are designed for operation at 230V rated voltage and 50/60Hz frequency, making them compatible with standard electrical systems in many regions. They meet...
Is private label manufacturing available for these products?
Yes, we offer ODM and private label manufacturing support for our Plug In RCBO Circuit Breakers, allowing businesses to integrate these products into their own branded offerings.
Project Inquiry
Streamline Your Electrical Protection Solutions
Contact Engineer today to discuss your project requirements or request a detailed quote for our Plug In RCBO Circuit Breakers.
Not sure which model to choose? Talk to an engineer
Visual References
Family Gallery
STANDARD COMPLIANCE
All components meet IEC 60947-2 and CE certification standards. ISO 9001:2015 certified manufacturing.
OEM/ODM CAPABILITIES
Custom electrical configurations and private labeling for global infrastructure projects.
ENGINEERING ASSETS
Immediate access to 2D/3D CAD models, STEP files, and detailed technical datasheets.
REQUIRE CUSTOM SPECIFICATIONS?
Consult with our lead engineers for a specialized BOM or system architecture review.